info@ogontz.com 800-523-2478
Design Features
  • Self-contained actuator
  • No external power or remote signal
  • In line serviceability
  • Insensitive to line pressure
  • Valve opens/closes gradually,preventing system shock
  • High repeatability: No set point drift
  • Set points from 35 to 255°F
  • Max working pressure 200 psig
  • 100% factory tested
Benefits
  • Easy installation
  • Reliable, unattended operation
  • Minimal maintenance requirements
Note: Specify temperature between 35° and 255°F in 5°F increments. Differential from full open to full closed is typically 10° to 15°F. Valve opens/closes gradually.

Unit of Measure

Specifications

NPT Inlet Thread Size

1-1/4 in

NPT Outlet Thread Size

1-1/4 in

Valve Type

AFR External Temperature Sensing Valve

Full Open Set Point Temperature Range

45 to 255 ºF

Port Size

1-1/16 in

Maximum Operating Pressure

125 psig

Flow Coefficient (Cv)

5.2

Valve Action

Reverse

Body Material

Brass

Dimensional Drawing


AFR/AFX Schematic Figure 2

Dimension A

2.13 in

Dimension B

8.62 in

Dimension C

2.41 in

Net Weight

5.3 lb

Plug Material

Urethane Viton

Optional Standard Leak Ports

LX - 1/4 to 1/2 GPM at 60 PSIG LZ - 1/2 to 1 GPM at 60 PSIG

The Ogontz Guarantee

We will repair or replace on a no-charge basis F.O.B. Willow Grove, PA, any Ogontz product returned to us within 18 months, if found to be defective in material or workmanship.